Slocable’s H1Z2Z2-K Twin-core solar cable is designed for harsh outdoor environments, using UV-resistant and weather-resistant insulation materials (XLPE/PVC) to withstand extreme temperatures from -40°C to +90°C and resist moisture and chemical corrosion. Its dual-core design simplifies installation, reduces wiring complexity and labor costs, while maintaining consistently stable performance.
| Type | Conductor
|
Insulation
|
Jacket
|
|||
| mm² | Wire struct
(±0.008) |
Conductor
diameter |
Thickness
(mm) |
Diameter
(±0.2mm) |
Thickness
(mm) |
Diameter
(±0.2mm) |
| 2*2.5 | 48/0.25*2 | 2 | 0.75 | 3.5 | 0.8 | 5.1*10.5 |
| 2*4 | 56/0.285*2 | 2.6 | 0.75 | 4 | 0.8 | 5.6*11.5 |
| 2*6 | 84/0.285*2 | 3.2 | 0.75 | 4.7 | 0.8 | 6.3*12.9 |
| 2*10 | 74/0.4*2 | 4 | 0.75 | 5.5 | 0.85 | 7.2*14.7 |
| 2*16 | 224/0.285*2 | 5.2 | 1 | 7.2 | 0.9 | 9.0*18.3 |
| Rated voltage | 1500V DC |
| Max. conductor temperature | +120°C |
| Maximum short-circuit temperature | 250ºC (max. 5 s). |
| Ambient temperature | -40~+90°C |
| Dielectric Strength(AC) | 6.5 KV/5Min. |
| Expected period of use | ≥25 years |
| Reference Standard | EN 50618:2014, IEC 62930 |
Advantage of PV Cable ·