UV resistant low voltage cable. Especially welsuited for outdoor applications due to the very robust outer sheath. Acc. to TÜV 2PfG 2954 for aluminium cables and protected, fixed installation in ground.
|
Construction |
||||||||
|
Type |
Conductor |
Insulation |
Jacket |
Conductor |
Min. insulation |
|||
|
Total |
Diameter of |
Thickness |
Diameter |
Thickness |
Diameter |
|||
|
2.5mm² |
48 |
0.25 |
1.1 |
4.3±0.2 |
0.8 |
5.9±0.2 |
8.210 |
1.204 |
|
4mm |
56 |
0.285 |
1.1 |
4.8±0.2 |
0.8 |
6.4±0.2 |
5.090 |
1.006 |
|
6mm² |
84 |
0.285 |
1.1 |
5.5±0.2 |
0.8 |
7.1±0.2 |
3.390 |
0.877 |
|
10mm² |
74 |
0.40 |
1.1 |
6.4±0.2 |
0.8 |
8.0±0.2 |
1.950 |
0.713 |
|
16mm² |
126 |
0.40 |
1.1 |
7.7±0.2 |
0.9 |
9.5±0.2 |
1.240 |
0.581 |
|
25mm |
192 |
0.40 |
1.3 |
9.4±0.2 |
1.0 |
11.4±0.3 |
0.795 |
0.543 |
|
35mm |
273 |
0.40 |
1.3 |
10.8±0.3 |
1.1 |
13.2±0.3 |
0.565 |
0.464 |
|
50mm² |
378 |
0.40 |
1.3 |
12.4±0.3 |
1.2 |
15.0±0.3 |
0.393 |
0.397 |
|
70mm² |
356 |
0.50 |
1.4 |
14.6±0.3 |
1.2 |
17.2±0.3 |
0.277 |
0.361 |
|
95mm |
485 |
0.50 |
1.4 |
16.6±0.3 |
1.3 |
19.5±0.3 |
0.210 |
0.322 |
|
120mm2 |
608 |
0.50 |
1.5 |
19.0±0.3 |
1.3 |
22.0±0.5 |
0.164 |
0.306 |
|
150mm2 |
756 |
0.50 |
1.6 |
21.4±0.5 |
1.4 |
24.6±0.5 |
0.132 |
0.294 |
|
185mm² |
925 |
0.50 |
1.7 |
24.0±0.5 |
1.6 |
27.8±0.5 |
0.108 |
0.283 |
|
240mm2 |
1221 |
0.50 |
1.8 |
26.8±0.5 |
1.7 |
30.6±0.5 |
0.082 |
0.263 |
| Rated voltage | 2000V DC |
| Conductor | CLASS 5 Copper, Tin plated |
| Max. conductor temperature | +120°C |
| Ambient temperature | -40~+90°C |
| Dielectric Strength(AC) | 8 KV/5Min. |
| Expected period of use | ≥25 years |
| Reference Standard | EN 50618:2014, IEC 62930 |
Slocable have passed many international certifications such as TUV Rheinland, UL4703, GSA, CE, and ROHS